Description
- Adaptable: Suitable for adult, pediatric, and neonatal patients, monitoring vital signals such as ECG, Respiratory Rate, SpO2, NIBP, TEMP, and IBP.
- All-in-One Design: Integrates parameter measuring modules, display, and recorder into one device, ensuring compactness, lightweight, and portability.
- Replaceable Battery: Built-in battery can be easily replaced, facilitating the transportation of patients and ensuring continuous monitoring.
- Clear Display: Large high-resolution display offers a clear view of 5 waveforms and full monitoring parameters, enhancing visibility and ease of use.
Features:
8 inch TFT color screen
Exquisite design suitable to moving operation
Various interfaces: standard screen, trend screen, oxyCRG screen, NIBP list screen, big front screen.
Real-time S-T segment analysis, pace-maker detection.
Built-in rechargeable lithium battery, convenient for patient moving.
Suitable for adult, pediatric and neonatal patient
Standard Configuration:
SpO2, PR, NIBP, ECG, RESP, TEMP
Technical Parameters:
ECG:
Lead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection:I, II, III, avR, avL, avF, V,
Waveform:2 ch
Gain:2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
Heart Rate:15-300BPM(Adult) 15-350BPM(Neonatal)
Accuracy:± 1% or ± 1bpm,which great
Resolution:1 bpm
ST measurement Range:-2.0-+2.0mV
Sweep Speed:12.5 mm/s,25mm/s,50mm/s
Alarm:Available
Review:Available
RESP:
Method Impedance between R-F(RA-LL)
Measuring Range:Adult 0 ~ 120 rpm,Neo/Ped 0 ~ 150 rpm
Resolution:1 rpm
Accuracy:±2 rpm
NIBP:
Method:Oscillometric
Mode:Manual, Auto, STAT
Measuring and alarm range
Adult Mode
SYS:40 ~ 270 mmHg
DIA:10 ~ 215 mmHg
MEAN:20 ~ 235 mmHg
Pediatric Mode
SYS:40 ~ 200 mmHg
DIA:10 ~ 150 mmHg
MEAN:20 ~ 165 mmHg
Neonatal Mode
SYS:40 ~ 135 mmHg
DIA:10 ~ 100 mmHg
MEAN:20 ~ 110 mmHg
Resolution:1mmHg
Accuracy:+-5mmHg
SpO2:
Measuring Range:0 ~ 100 %
Alarm Range:0 ~ 100 %
Resolution:1 %
Accuracy:70% ~ 100% ±2 %
Actualization interval:about 1 Sec.
Alarm Delay:10 Sec.
Pulse Rate :0~254bpm
Resolution:1bpm
Accuracy:±2bpm
Temperature:
Measuring and Alarm Range:0 ~ 50 C
Resolution:0.1C
Accuracy:0.1C
Actualization interval:about 1 Sec.
Average Time Constant:< 10 Sec.
Package List:
Patient monitor
Temperature probe
ECG lead cable
ECG electrode
Adult NIBP cuff
NIBP extension tube
Adult fingertip SpO2 probe
Power cord
User Manual
Payment & Security