10 Inch Multi-parameter Monitor ICU CCU Vital Sign Dental Patient Monitor ECG NIBP RESP TEMP SPO2 PR

SKU: 181054
filler

Price:
$369.99

Description

Introducing our Portable Dental Oral Implant Patient Monitor, ideal for adult, pediatric, and neonatal use during oral implant surgeries. This versatile device provides real-time vital sign monitoring, particularly beneficial for patients with cardiovascular, cerebrovascular, and diabetic conditions. Ensure precise monitoring and improved patient care with our user-friendly monitor.

Features:

Experience Clear Monitoring with our 10-inch High-Resolution TFT Display Monitor:

  • Customizable Alarms: Set alarm limits as needed, with automatic sound and light alerts for added safety.
  • Enhanced Safety Features: Anti-movement, anti-defibrillation, and anti-electrosurgical interference ensure reliable monitoring in any environment.
  • Network Compatibility: Remote central monitoring network interface enables seamless integration for comprehensive patient care.
  • Advanced Functions: Includes drug solubility calculation and arrhythmia analysis for thorough patient assessment.
  • Long-lasting Performance: Equipped with a built-in lithium battery and AC/DC power options, ensuring uninterrupted monitoring even during power outages.
  • Versatile Application: Widely used across various medical departments, from internal medicine to dental practices, surgery centers, and emergency departments.
  • Standard Configuration: ECG, NIBP, SPO2, TEMP, RESP, and PR.



Specification:

ECG

Lead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection:I, II, III, avR, avL, avF, V,

Waveform:2 ch

Lead mode:3 Leads ( R, L, F or RA, LA, LL)

Lead selection:I, II, III,

Waveform:1 ch

Gain:´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto

Alarm 

Range: 

Adult:15 ~ 300 bpm

Neo/Ped:15 ~ 350 bpm

Accuracy:± 1% or ± 1bpm,which great

Resolution:1 bpm

Sensitivity:> 200 (uV P-P)

Differential Input Impedance:> 5 MΩ

RESPARATION:

Method:Impedance between R-F(RA-LL)

Differential Input Impedance:>2.5 MΩ

Measuring Impedance Range:0.3~5.0Ω

Base line Impedance Range:0 – 2.5  KΩ

Bandwidth:0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range 

Adult:0 ~ 120 rpm

Neo/Ped:0 ~ 150 rpm

Resolution:1 rpm

Accuracy:±2 rpm

Apean Alarm:10 ~ 40 S

NIBP

Method:Oscillometric

Mode:Manual, Auto, STAT

Measuring Interval in AUTO Mode

 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

Measuring Period in STAT Mode:5 Min

Pulse Rate Range:40 ~ 240 bpm

Alarm Type:SYS, DIA, MEAN

Measuring and alarm range:   

Adult Mode

SYS :40 ~ 270 mmHg

DIA :10 ~ 215 mmHg

MEAN:20 ~ 235 mmHg

Pediatric Mode

SYS:40 ~ 200 mmHg

DIA:10 ~ 150 mmHg

MEAN:20 ~ 165 mmHg

Neonatal Mode

SYS:40 ~ 135 mmHg

DIA:10 ~ 100 mmHg

MEAN:20 ~ 110 mmHg

Overpressure Protection

Adult Mode:297±3 mmHg

Pediatric Mode:240±3 mmHg

Neonatal Mode:147±3 mmHg

SpO2

Measuring Range:0 ~ 100 %

Alarm Range:0 ~ 100 %

Resolution:1 %

Accuracy:     

70% ~ 100%  ±2 %

0%  ~  69%  unspecified

Actualization interval:about 1 Sec.

Alarm Delay:10 Sec.

Pulse Rate

Measuring and Alarm Range:0~254bpm

Resolution:1bpm

Accuracy:±2bpm

I.5TEMP measurement:

Channel:1

Measuring and Alarm Range:0 ~ 50 °C

Resolution:0.1°C

Accuracy:±0.1°C

Actualization interval:about 1 Sec.

Average Time Constant:< 10 Sec.

Package List:

1×Dental Patient Monitor

EKG Lead wire

1×NIBP Cuff

1×NIBP Extension Cable

1×SpO2 Sensor

1×Temp Sensor

3×Limp Clip

5×Electrode

1×User Manual