Description
Introducing our Portable Dental Oral Implant Patient Monitor, ideal for adult, pediatric, and neonatal use during oral implant surgeries. This versatile device provides real-time vital sign monitoring, particularly beneficial for patients with cardiovascular, cerebrovascular, and diabetic conditions. Ensure precise monitoring and improved patient care with our user-friendly monitor.
Features:
Experience Clear Monitoring with our 10-inch High-Resolution TFT Display Monitor:
- Customizable Alarms: Set alarm limits as needed, with automatic sound and light alerts for added safety.
- Enhanced Safety Features: Anti-movement, anti-defibrillation, and anti-electrosurgical interference ensure reliable monitoring in any environment.
- Network Compatibility: Remote central monitoring network interface enables seamless integration for comprehensive patient care.
- Advanced Functions: Includes drug solubility calculation and arrhythmia analysis for thorough patient assessment.
- Long-lasting Performance: Equipped with a built-in lithium battery and AC/DC power options, ensuring uninterrupted monitoring even during power outages.
- Versatile Application: Widely used across various medical departments, from internal medicine to dental practices, surgery centers, and emergency departments.
- Standard Configuration: ECG, NIBP, SPO2, TEMP, RESP, and PR.
Specification:
ECG
Lead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection:I, II, III, avR, avL, avF, V,
Waveform:2 ch
Lead mode:3 Leads ( R, L, F or RA, LA, LL)
Lead selection:I, II, III,
Waveform:1 ch
Gain:´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto
Alarm
Range:
Adult:15 ~ 300 bpm
Neo/Ped:15 ~ 350 bpm
Accuracy:± 1% or ± 1bpm,which great
Resolution:1 bpm
Sensitivity:> 200 (uV P-P)
Differential Input Impedance:> 5 MΩ
RESPARATION:
Method:Impedance between R-F(RA-LL)
Differential Input Impedance:>2.5 MΩ
Measuring Impedance Range:0.3~5.0Ω
Base line Impedance Range:0 – 2.5 KΩ
Bandwidth:0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult:0 ~ 120 rpm
Neo/Ped:0 ~ 150 rpm
Resolution:1 rpm
Accuracy:±2 rpm
Apean Alarm:10 ~ 40 S
NIBP
Method:Oscillometric
Mode:Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode:5 Min
Pulse Rate Range:40 ~ 240 bpm
Alarm Type:SYS, DIA, MEAN
Measuring and alarm range:
Adult Mode
SYS :40 ~ 270 mmHg
DIA :10 ~ 215 mmHg
MEAN:20 ~ 235 mmHg
Pediatric Mode
SYS:40 ~ 200 mmHg
DIA:10 ~ 150 mmHg
MEAN:20 ~ 165 mmHg
Neonatal Mode
SYS:40 ~ 135 mmHg
DIA:10 ~ 100 mmHg
MEAN:20 ~ 110 mmHg
Overpressure Protection
Adult Mode:297±3 mmHg
Pediatric Mode:240±3 mmHg
Neonatal Mode:147±3 mmHg
SpO2
Measuring Range:0 ~ 100 %
Alarm Range:0 ~ 100 %
Resolution:1 %
Accuracy:
70% ~ 100% ±2 %
0% ~ 69% unspecified
Actualization interval:about 1 Sec.
Alarm Delay:10 Sec.
Pulse Rate
Measuring and Alarm Range:0~254bpm
Resolution:1bpm
Accuracy:±2bpm
I.5TEMP measurement:
Channel:1
Measuring and Alarm Range:0 ~ 50 °C
Resolution:0.1°C
Accuracy:±0.1°C
Actualization interval:about 1 Sec.
Average Time Constant:< 10 Sec.
Package List:
1×Dental Patient Monitor
1×EKG Lead wire
1×NIBP Cuff
1×NIBP Extension Cable
1×SpO2 Sensor
1×Temp Sensor
3×Limp Clip
5×Electrode
1×User Manual
Payment & Security